About 50 results
Open links in new tab
  1. Deflection Limits | Eng-Tips

    Aug 3, 2001 · Dougantholz - It seems that deflection limits are up to the engineer who is designing, and not to exceed the limits set forth in code (l/240, l/360, l/600, etc.). Lets just say an l/360 delf. limit for …

  2. Deflection and Rotation of a Simple Beam With a Partially Distributed ...

    Oct 31, 2025 · Many users have historically asked how to determine the deflection and rotation equations for a simple beam with a partially distributed uniform load (case 4 in table 3-23 of the AISC …

  3. Canopy Deflection | Eng-Tips

    Oct 23, 2025 · I am being asked to design a cantilever steel canopy above a parking lot. The design is to be based upon a single column supporting an outrigger beam (either T or L shaped depending on …

  4. Is the 0.6 wind load reduction(ASD) just to check deflection?

    Nov 12, 2013 · ASD is not just for deflection checks. ASD is to check the capacity of the member (allowable stress for wood, allowable strength for steel) against the expected load. If you're using …

  5. Modifying cantilever beam deflection and breaking load equations for ...

    Aug 31, 2025 · Hi, I am writing a calculator for sizing up free-standing masts for small boats, and I need to estimate their deflection at a certain load, and the breaking load to get a safety factor. The masts …

  6. Deflection Criterias for Folding Partition | Eng-Tips

    Oct 18, 2010 · This 1" deflection will be present when the track for the folding partition is installed. Is the curvature of the track the reason for the stringent deflection criteria or is it the fact the folding partition …

  7. Large Disk Supported in Center - Deflection | Eng-Tips

    Feb 16, 2018 · 10 in. Both the inner and outer edges are simply supported, and it is required to determine the maximum deflection and maximum stress as a function of the plate thickness. Once …

  8. Building Code deflection limits perpendicular to joist/truss spans

    Apr 13, 2020 · The IBC Floor and Roof deflection limits are frequently applied in the following manner for wood framing. The deflection of each floor joist or roof truss is checked to meet L/360 for Live Load, …

  9. Enercalc Masonry Slenderwall Deflection | Eng-Tips

    Apr 11, 2023 · Wall deflection should be at allowable levels, if I was doing it by hand. Florida building code allows deflection to be checked at 0.42W component and cladding, but even at 0.6W the …

  10. Stiffness modifiers for deflection check in beams | Eng-Tips

    Jul 15, 2015 · Hi, Table 6.6.3.1.1 provides property modifiers for beams for factored load level analysis. Ie = 0.35Ig. Section 6.6.3.2.2 says it is permitted to calculate immediate lateral deflection using 1.4 …